摘要: 利用光通量方法对分离式霍普金森压剪杆实验技术中的剪切应变测量进行了实验研究。实验装 置主要包括:准直激光器、光电接收器、光学挡板。由装置性能验证实验结果以及不确定度分析结果表明:利 用基于光通量法的剪切应变测量技术能够可靠地测量SHPSB(splitHopkinsonpressurebar)试样的剪切应 变。并对比了基于光通量法测量的剪切应变值与理论近似结果,结果显示前者小于后者,分析并讨论了原因。Abstract: AtechniquebasedonluminousfluxmethodwasappliedtomeasureshearstraininSHPSB (splitHopkinsonpressurebar)experiment.Theopticalsetupconsistedofthreemajorcomponents:a collimationlaser,aphotoelectricsensingapparatusandtwoopticalbaffles.Resultsfromavalidexperimentandanuncertaintyanalysisshowedthatitwaseffectiveandaccuratetogettheshearstrain ofthespecimen.Theshearstrainmeasuredbytheopticalapparatuswascomparedwiththetheoretic ones.Itwasfoundandanalyzedthatthemeasuredshearstrainwaslessthanthatofthetheoryinvalue
-
Key words:
- solidmechanics /
- SHPSB /
- combinedcompression-shearloading /
- luminousfluxmethod /
- shearstrain
计量
- 文章访问数: 2697
- HTML全文浏览量: 114
- PDF下载量: 234
- 被引次数: 0