Introduces some new developments in nonauditory damage assessment method exposed to complex waves, analyzes feature and applicable range of these nonauditory damage assessment methods. Max inward chest velocity method, effective peak method and injury software method are the most adopted methods in nonauditory damage assessment. The organ response in thorax and abdomen and injury mechanism researched by finite element method is further direction of research on complex waves.