摘要:
为研究爆炸荷载作用下不锈钢管混凝土(concrete-filled stainless steel tubular,CFSST)柱的损伤特征、残余轴向承载性能及爆炸后轴压破坏模式,开展了CFSST柱野外爆炸试验、爆炸损伤试件轴压试验及无损试件轴压试验,建立并验证了LS-DYNA有限元模型,分析了不同爆炸工况下CFSST柱的破坏模式及不同初始损伤状态下试件的轴压破坏模式。研究表明,CFSST柱的爆炸损伤主要集中于柱跨中迎爆区域,不锈钢管出现局部凹陷和侧向鼓曲。有限元模型能够较好地复现CFSST柱的爆炸损伤形态、动力响应及爆后轴压承载性能。随着比例距离减小,CFSST柱的破坏模式由整体弯曲破坏模式逐渐转变为局部凹陷、侧向鼓曲与整体弯曲共同作用的复合破坏模式。爆炸后形成的跨中残余弯曲使CFSST柱在后续轴压过程中产生附加弯矩,爆炸初始损伤削弱了不锈钢管与混凝土的协同工作能力,导致轴压破坏控制位置由加载端向试件中部转移。随着初始损伤的减小,损伤柱的轴压破坏模式由中部屈曲破坏逐渐转变为端部与中部共同屈曲破坏,最终转变为无损柱的加载端屈曲破坏。
Abstract:
To investigate the damage characteristics, residual axial load-carrying performance, and post-blast axial compression failure modes of concrete-filled stainless steel tubular (CFSST) columns subjected to blast loading, field blast tests, post-blast axial compression tests, and axial compression tests on intact specimens were conducted. The specimens had a square cross-section of 250 mm × 250 mm, a total length of 3000 mm, and a stainless steel tube thickness of 3 mm. In the blast test, a 6 kg TNT charge was detonated at a standoff distance of 300 mm from the mid-height blast-facing surface, while an initial axial compression ratio of 0.2 was applied. An LS-DYNA finite element model based on the multi-material arbitrary Lagrangian-Eulerian method was then established and validated to reproduce blast-wave propagation, fluid-structure interaction, structural damage, and the subsequent axial compression response. The results show that the blast-induced damage was mainly concentrated in the mid-height blast-facing region, where local indentation and lateral outward buckling developed in the stainless steel tube, while the overall integrity of the column was maintained. The maximum indentation depth measured in the test was 37 mm. The validated numerical model reasonably reproduced the damage pattern, displacement response, acceleration response, and post-blast axial load-displacement behavior. The errors between the experimental and numerical peak displacement, peak acceleration, and peak axial load were 1.5%, 5.6%, and 5.0%, respectively. The blast-damaged specimen reached a peak axial load of 1572.2 kN, which was 50.4% lower than that of the intact specimen. As the scaled distance decreased, the failure mode gradually changed from overall flexural failure to a combined failure mode involving local indentation, lateral outward buckling, and overall flexural deformation. The residual flexural deformation generated additional bending moments during subsequent axial compression, while the initial blast damage weakened the composite action between the stainless steel tube and the core concrete. As the initial damage decreased, the axial compression failure mode of the blast-damaged columns gradually changed from mid-height buckling to combined loading-end and mid-height buckling, and ultimately to loading-end buckling in the intact column. These findings provide a basis for the blast-resistant design and post-blast safety assessment of CFSST columns.